Multifunctional measuring complex

Multifunctional measuring complex«Alma Meter-2».

Within the framework of the subprogram “Scientific and educational equipment” of the SSTP “Standards and Scientific Instruments”, BSU developed and manufactured prototypes of the multifunctional measuring complex “Alma Meter-2”.

The Alma Meter – 2 complex is a development of the approach tested during the creation of the Alma Meter multifunctional measuring complex (see photo on the right) and represents a new generation of measuring equipment having the best technical, metrological and functional characteristics.

The Alma Meter – 2 complex includes 11 types of measuring modules for various purposes, each of which can be used both as part of a measuring station together with other measuring modules, and as a separate measuring device. In addition, there is a base unit with a built-in power supply for the modules and an interface, as well as a laboratory DC power source (see figure to the left).

Depending on the needs of the customer, an arbitrary combination of measuring modules, basic and laboratory units can be included in the complex.

Each of the measuring modules is a computer-oriented device with two high-speed interfaces - USB 3.1 / 2.0 and 1 Gbit / 100 Mbit LAN.

The multifunctional measuring complex “Alma Meter 2” can be successfully applied in educational and research laboratories in teaching students, conducting course, degree and research works.

Detailed ...

Digital oscilloscopes

B-321 Digital oscilloscope

- number of input channels - 2;

- input channel bandwidth - from 0 to 300 MHz;

- sampling frequency for one-time signals - up to 1 GSa / s;

- sampling frequency in the mode of equivalent samples - up to 20 GSa / s;

- vertical resolution - 8 bits;

- vertical deviation coefficients - from 2 mV / div to 5 V / div;

- limits of permissible main reduced error in voltage measurement - ± 1%;

- range of sweep factors - from 5 ns / div to 1 s / div;

Detailed  ...

B-322 Digital oscilloscope

- number of input channels - 2;

- input bandwidth - from 0 to 150 MHz;

- sampling frequency for single signals - up to 200 MSa / s;

- sampling frequency in the mode of equivalent samples - up to 10 GSa / s;

- vertical resolution - 10 bits;

- vertical deviation coefficients - from 5 mV / div. Up to 5 V / div;

- limits of permissible main reduced error in voltage measurement - ± 1%;

- range of sweep factors - from 5 ns / div to 1 s / div;

Detailed  ...

 

B-424 Digital oscilloscope


- Number of input measuring channels - 2

- Input path bandwidth - 0 ... 200 MHz

- Open / closed input 1 MΩ, work with a standard remote divider

- Hardware offset of input signal level within wide limits

- Vertical resolution - 8 bits

- The basic error is ± 1%.

- 11 calibrated vertical deviations in 1-2-5 steps:

without divider - 2 mV / div ... 5 V / div

with divider 1:10 - 20 mV / div ... 50 V / div

Detailed  ...

B-423 Digital oscilloscope

- Number of input measuring channels - 2

- Input path bandwidth - 0 ... 150 MHz

- Open / closed input 1 MΩ, work with a standard remote divider

- Hardware offset of input signal level within wide limits

- Vertical resolution - 10 bits

- The basic error is ± 1%. With remote divider 1:10 - ± 2%

- 11 calibrated vertical deviations in 1-2-5 steps:

   without divider - 2 mV / div ... 5 V / div

   with divider 1:10 - 20 mV / div ... 50 V / div

Detailed  ...

B-422 Digital oscilloscope

- Number of input measuring channels - 2

- Input path bandwidth - 150 MHz

- Vertical resolution - 10 bits

- Open / closed input 1 MΩ, work with a standard remote divider

- Hardware input level offset plus or minus input range

- 7 calibrated vertical deviations in 1-2-5 steps:

    without divider - 5 mV / div ... 5 V / div

    with divider 1:10 - 50 mV / div ... 50 V / div

Detailed  ...

B-411 Digital oscilloscope

- Number of input measuring channels - 1

- Input path bandwidth - 150 MHz

- Vertical resolution - 10 bits

- Open / closed input 1 MΩ, work with a standard remote divider

- Hardware input level offset plus or minus input range

- 7 calibrated vertical deviations in 1-2-5 steps:

    without divider - 10 mV / div ... 1 V / div

    with divider 1:10 - 100 mV / div ... 10 V / div

Detailed ...

B-222 Digital oscilloscope

- Number of input measuring channels - 2

- Input path bandwidth - 150 MHz

- Vertical resolution - 8 bits

- Open / closed input 1 MΩ, work with a standard remote divider

- Hardware input level offset plus or minus input range

- 7 calibrated vertical deviations in 1-2-5 steps:

    without divider - 10 mV / div ... 1 V / div

    with divider 1:10 - 100 mV / div ... 10 V / div

Detailed ...

B-221 Digital oscilloscope

- Number of input measuring channels - 2

- Input path bandwidth - 150 MHz

- Vertical resolution - 8 bits

- Open / closed input 1 MΩ, work with a standard remote divider

- Hardware input level offset plus or minus input range

- 7 calibrated vertical deviations in 1-2-5 steps:

    without divider - 10 mV / div ... 1 V / div

    with divider 1:10 - 100 mV / div ... 10 V / div

Detailed ...

B-211 Digital oscilloscope

- Number of input measuring channels - 1

- Input path bandwidth - 150 MHz

- Open / closed input 1 MΩ, work with a standard remote divider

- Hardware input level offset plus or minus input range

- Vertical resolution - 10 bits

- 7 calibrated vertical deviations in 1-2-5 steps:

    without divider - 10 mV / div ... 1 V / div

    with divider 1:10 - 100 mV / div ... 10 V / div

Detailed ...

Arbitrary waveform generators

Arbitrary waveform generator В-331

- number of output channels - 2;

- output resistance - 50 Ohm;

- sampling frequency of the signal generated by the generator - 250 MHz;

- bit D / A - 16 bits;

- frequency range generated by the generator of periodic signals - from 0.1 Hz to 10 MHz;

- output voltage ranges: ± 8 V (± 4 V) when operating at a load of ≥10 kΩ (50 Ω);

- types of generated signals: DC voltage; sinusoidal; rectangular shape; triangular shape; pseudo-random -

noise; analytically specified signal.

Detailed ...

Wideband Signal Generator  B-333

- number of output channels - 2;

- output resistance - 50 Ohm;

- frequency range of the generated signals - from 0 to 300 MHz;

- bit D / A - 12 bits;

- overall dimensions – 115x40x190 mm;

- weight - 0.4 kg.

Detailed ...

 

Arbitrary Waveform Generator B-332

- Number of output channels - 2

- Output impedance channels - 50 ohms

- Output voltage ranges of the generated signals:

    1 - ± 2 V (± 1 V) when operating at a load of 1 kΩ (50 Ω)

    2 - ± 8 V (± 4 V) when operating at a load of 1 kΩ (50 Ω)

- DAC resolution - 14 bits

- Voltage resolution:

    range ± 2 V - 0.25 mV

    range ± 8 V - 1 mV

Detailed ...

Generator arbitrary waveform AGENT B-230

- Number of output channels - 1

- Output impedance channels - 50 ± 2.5 Ohm

- Output voltage ranges of the generated signals, not less:

    ± 3 V (± 1.5 V) when operating at a load of 1 kΩ (50 Ω)

    ± 8 V (± 4 V) when operating at a load of 1 kΩ (50 Ω)

- DAC resolution - 14 bits

- Voltage resolution, not worse:

    range ± 3 V - 0.4 mV

    range ± 8 V - 1 mV

- Parameters of built-in control ADC:

    Input voltage range ± 10 V

    Digitality - 14 bits

Detailed ...

Digital Signal Generators

Analyzer-generator of digital signals V-341

- number of input channels of the analyzer - 8 (the digital signals under study are received through the active probe);

- the number of output channels of the digital generator - 8 (removed from the output connectors of the remote unit of the digital generator);

- channel input parameters of the active probe:

- input resistance - at least 100 kΩ;

- input capacitance - no more than 10 pF.

- logical levels of the generated digital signals of the digital generator channels:

- output voltage of low level Uout 0 - no more than 0.4 V;

- output voltage of high level Uout1 - not less than 2.5 V.

Detailed  ...

Digital Signal Analyzer B-441

- Number of input measuring channels - 8

- Input parameters - 100 kΩ, 10 pF

- Input range - ± 15 V

- Setting the level of discrimination of input signals ± 5 V with an accuracy of 150 mV

Detailed  ...

Multichannel ADC

High-speed analog signal recorder B-386

Number of input channels - 2;

sampling frequency - up to 100 MSa / s (single channel mode);

resolution - 16 bits;

input range of measured voltages - ± 10 V;

buffer memory size - 64 Msw per channel;

relative (reduced to the input range) error measurement voltage constant level - 0.1%;

overall dimensions – 150x50x190 mm;

weight - 0.5 kg.

Detailed  ...

Analog Signal Recorder B-384

- number of isolated input measuring channels - 4;

- galvanic isolation (voltage up to 500 V) of each of the measuring channels from each other and from the interface with the control computer;

- input impedance of each of the measuring channels - 1 MΩ;

- input range of measured voltages - ±10 V;

- bit ADC - 16 bits;

- relative (reduced to the input range) error measurement voltage constant level - 0.1%;

- maximum sampling rate of ADC - 1 MSa / s;

- overall dimensions – 115x40x190 mm;

- weight - 0.4 kg.

Detailed  ...

Recording Converter – Multimeter B-385

- number of voltage measurement channels - 2;

- voltage measurement range - from 0.01 to 30 V;

- number of current measurement channels - 2;

- current measurement range - from 0.00001 to 1 A;

- resolution of voltage and current measurement channels - 50,000 gradations;

- sampling frequency of measuring channels - 100 vib / s.

- overall dimensions – 115x40x190 mm;

- weight - 0.4 kg. 

Detailed  ...

Measuring instrument of signals from sensors with the bridge scheme of connection В-362

- provides registration of signals from full-bridge and half-bridge switching circuits using four differential measurement channels;

- number of measuring channels - 4;

- bit ADC - 16 bits;

- sampling frequency range - from 1 vyb / s to 250 kw / s;

- maximum memory depth - 1 MSa / channel;

- voltage of the built-in reference voltage source 5 V;

- rated power supply current of external sensors 70 mA;

- input signal ranges from 10 to 40 mV;

- the limits of the resulted error of measurement of a voltage of a direct current - ±0,2%.

- overall dimensions – 115x40x190 mm;

- weight - 0.4 kg.

Detailed  ...

Signal meter from ICP sensors В-363

- designed to register signals from ICP-type sensors.

- number of measuring channels - 4;

- input signal range - ±2.5 V;

- bit ADC - 16 bits;

- sampling frequency range - from 1 vyb / s to 250 kw / s;

- maximum memory depth - 1 MSa / channel;

- ICP type supply current value at the channel output - 4 mA, 10 mA (in the voltage range from 0.5 to 22 V);

- limits of the resulted error of measurement of voltage of an alternating current - ±0,2%.

- overall dimensions – 115x40x190 mm;

- weight - 0.4 kg.   

Detailed  ...

Temperature meter B-391

- Designed to measure and record signals from J-, K-type thermocouples and PT100 type temperature sensors

- number of measuring channels - 4;

- bit ADC - 16 bits;

- sampling frequency range - from 1 vyb / s to 100 kw / s;

- temperature measurement range when connecting external sensors:

- from minus 50 to plus 250 °С for the PT100 sensor;

- from minus 10 to plus 50 °С for type K and type J thermocouples;

- limits of temperature measurement error:

- for channel with PT100 sensor - ± 0.7 °С

- for channels with thermocouples of tick K and J - ± 1.5 °С

- overall dimensions – 115x40x120 mm;

- weight - 0.4 kg.

Detailed  ...

Multichannel ADC B-480

- Number of measuring channels - 8

- Digit capacity - 16 bits

- Speed:

250 kv / s (R source signal not more than 1 kΩ)

100 kv / s (R source signal not more than 1 MΩ)

- Input resistance - at least 1 MΩ

- Input range ± 10 V

- Input protection ± 20 V

- Galvanic isolation - up to 1000 V (no modification in B-480 *)

Detailed  ...

Multichannel ADC В-281

- Number of measuring channels - 32- Digit - 16 bits

- Speed

    250 kv / s (R source signal not more than 1 kOm)

    100 kv / s (R source signal not more than 1 MOm)

- Input resistance - at least 1 MOm

- Input signal ranges ± 10 V, ± 5 V, ± 2.5V, ± 1.25V

- Input protection ± 20 V

Detailed  ...

Measuring instrument of time intervals

Measuring instrument of time intervals В-471

 

- Number of input measuring channels - 2

- Amplitude range of input signals - from 0.5 to 50 V

- Resolution 2.5 ns

- Measurement range of time intervals from 10 ns to 1000 s

- Setting the level of discrimination of input signals / installation error:

    with the attenuation coefficient of the built-in attenuator 1: 1 - ± 4 V / ± 0.1 V

    with the attenuation coefficient of the built-in attenuator 1:10 - ± 40 V / ± 1 V

Detailed ...

Thermal imaging system for measuring high temperatures

Thermovisor IT-3CM

IT-3CM consists of a special-purpose digital video block that records thermal radiation in three overlapping spectral regions, which lie in the range 630–830 nm, and a standard laptop. The SVGA matrix of photodetectors with the number of active elements 752 × 480 is used.

The use of IT-3CM is effective in setting up and monitoring various high-temperature heat engineering processes. The functionality of the thermal imager is significantly expanded compared with traditional partial radiation and spectral pyrometers, as well as thermal imagers of the mid-infrared range of the spectrum. Registration of the thermal field in three parts of the spectrum allows one to determine the approximate values ​​of the effective coefficients of thermal radiation ε1, ε2, ε3 in these areas and to form the field of the true temperatures of the monitored object.

Detailed ...

System diagnostics of operating parameters of machines and mechanisms

Recorder of parameters of the movement of the lift lifting equipment B-590 "Paltus"

The recorder of motion parameters of elevator lifting equipment B-590 "PALTUS" is intended for measuring vibration acceleration during the motion of a lifting mechanism, calculation, recording and indication of motion parameters. The device is a portable device with an indicator, keyboard, power supply and magnetic holders. The device registers the acceleration values of the investigated hoisting mechanisms along three perpendicular axes in the internal non-volatile memory. In the process of measurements on the indicator of the device can display the average or root-mean-square value of the acceleration along one of the measuring axes. Upon completion of the data registration process, the device performs the primary calculation and display on the screen the maximum and minimum peak acceleration values, the maximum linear velocity value. Initial processing of the measurement data in the device and displaying the results on the built-in screen allows you to quickly assess the technical condition of the lifting mechanism. A more detailed analysis of the recorded data is provided to the user on a computer to which the device can be connected via USB

Detailed ...

Auxiliary equipment and accessories

Cash desk of chip resistors and capacitors for radio equipment СЕ24
Convenient, reliable design, proven by many years of operating experience
Row E24
Sizes: 0805, 0603
Accuracy (for resistors): 5%, 1%
Dielectric Type (for capacitors) NPO, X7R
Capacity: from 100 pcs of each face value

Detailed ...

Oscillographic Remote Dividers
Division ratio: 1:1/1:10/1:100
Bandwidth: 150, 250 MHz
Nozzle set